R-Class 220℃ Insulation VPI Transformer Dry Type High-Temperature Resistant Vacuum Pressure Impregnated Transformer
WINLEY Electric’s vacuum-impregnated dry-type transformers with R-class insulation feature the NOMEX insulation system. Endowed with high heat resistance and strong overload capability, this system ensures superior performance and safety for the transformers even in prolonged high-temperature conditions.
Product factory photos
![]()
![]()
![]()
![]()
Insulation class classification
As per NEMA class of insulation for transformer is based on the max. An R-Class insulation transformer uses very high-temperature resistant materials, allowing its windings to reach a maximum hot-spot temperature of 220°C.
| Insulation Class | Maximum allowable temperature rise (°C) |
environmental temperature (°C) |
Maximum Temperature (°C) |
Common Insulation Materials |
| Class A | 50 | 40 | 105 | Cotton, Paper, Silk, Wood |
| Class B | 80 | 40 | 130 | Mica, Fiberglass, Asbestos, etc., with suitable bonding substances |
| Class F | 105 | 40 | 155 | plus materials like synthetic enamelsB |
| Class H | 125 | 40 | 180 | Silicone elastomers, Mica, Fiberglass with high-temperature bonding substances |
| Class R | 150 | 40 | 220 | Very high-temperature resistant materials, often proprietary |
Performance Characteristic
Technical drawings
![]()
Application Areas:
Specification
| Model (kva) |
Primary Voltage | Secondary Voltage | Coupling group tab | Shape dimension | Mounting dimension | K*J | The box dimension | |||||
| Bmax | Dmax±5 | Emax | A | C±5 | Bmax | Dmax±5 | Emax | |||||
| SG-10KVA | 660 400 380 200 |
380 220 110 36 |
Yyn0 Y/d D/y D/d |
360 | 180 | 305 | 215 | 140 | 10*20 | 450 | 360 | 480 |
| SG-15KVA | 360 | 200 | 335 | 215 | 155 | 10*20 | 450 | 360 | 480 | |||
| SG-20KVA | 420 | 210 | 350 | 250 | 170 | 10*20 | 490 | 400 | 540 | |||
| SG-30KVA | 420 | 230 | 380 | 250 | 190 | 10*20 | 490 | 400 | 540 | |||
| SG-50KVA | 680 | 350 | 550 | 420 | 220 | 10*20 | 800 | 510 | 840 | |||
| SG-80KVA | 750 | 400 | 620 | 480 | 250 | 10*20 | 850 | 510 | 840 | |||
| SG-100KVA | 780 | 420 | 650 | 500 | 250 | 10*20 | 900 | 550 | 890 | |||
| SG-300KVA | 180 | 95 | 185 | 100 | 75 | 6*14 | ||||||
| SG-500KVA | 180 | 95 | 185 | 100 | 75 | 6*14 | ||||||
| SG-1000KVA | 180 | 110 | 185 | 100 | 90 | 6*14 | ||||||
| SG-2000KVA | 230 | 125 | 205 | 130 | 100 | 9*16 | ||||||
| SG-3000KVA | 240 | 145 | 215 | 130 | 120 | 9*16 | ||||||
| SG-4000KVA | 240 | 155 | 235 | 130 | 130 | 9*16 | ||||||
| SG-5000KVA | 320 | 160 | 255 | 180 | 115 | 10*20 | 400 | 330 | 480 | |||
| SG-6000KVA | 300 | 165 | 280 | 180 | 140 | 10*20 | 400 | 330 | 480 | |||
Production process
![]()
|
| Nom De Marque: | WINLEY |
| Numéro De Modèle: | SG-2000KVA/6.9 |
| Nombre De Pièces: | 1Unité |
| Prix: | $500~$60000/Unit |
| Détails De L'emballage: | caisse en contreplaqué |
| Conditions De Paiement: | T/T |
R-Class 220℃ Insulation VPI Transformer Dry Type High-Temperature Resistant Vacuum Pressure Impregnated Transformer
WINLEY Electric’s vacuum-impregnated dry-type transformers with R-class insulation feature the NOMEX insulation system. Endowed with high heat resistance and strong overload capability, this system ensures superior performance and safety for the transformers even in prolonged high-temperature conditions.
Product factory photos
![]()
![]()
![]()
![]()
Insulation class classification
As per NEMA class of insulation for transformer is based on the max. An R-Class insulation transformer uses very high-temperature resistant materials, allowing its windings to reach a maximum hot-spot temperature of 220°C.
| Insulation Class | Maximum allowable temperature rise (°C) |
environmental temperature (°C) |
Maximum Temperature (°C) |
Common Insulation Materials |
| Class A | 50 | 40 | 105 | Cotton, Paper, Silk, Wood |
| Class B | 80 | 40 | 130 | Mica, Fiberglass, Asbestos, etc., with suitable bonding substances |
| Class F | 105 | 40 | 155 | plus materials like synthetic enamelsB |
| Class H | 125 | 40 | 180 | Silicone elastomers, Mica, Fiberglass with high-temperature bonding substances |
| Class R | 150 | 40 | 220 | Very high-temperature resistant materials, often proprietary |
Performance Characteristic
Technical drawings
![]()
Application Areas:
Specification
| Model (kva) |
Primary Voltage | Secondary Voltage | Coupling group tab | Shape dimension | Mounting dimension | K*J | The box dimension | |||||
| Bmax | Dmax±5 | Emax | A | C±5 | Bmax | Dmax±5 | Emax | |||||
| SG-10KVA | 660 400 380 200 |
380 220 110 36 |
Yyn0 Y/d D/y D/d |
360 | 180 | 305 | 215 | 140 | 10*20 | 450 | 360 | 480 |
| SG-15KVA | 360 | 200 | 335 | 215 | 155 | 10*20 | 450 | 360 | 480 | |||
| SG-20KVA | 420 | 210 | 350 | 250 | 170 | 10*20 | 490 | 400 | 540 | |||
| SG-30KVA | 420 | 230 | 380 | 250 | 190 | 10*20 | 490 | 400 | 540 | |||
| SG-50KVA | 680 | 350 | 550 | 420 | 220 | 10*20 | 800 | 510 | 840 | |||
| SG-80KVA | 750 | 400 | 620 | 480 | 250 | 10*20 | 850 | 510 | 840 | |||
| SG-100KVA | 780 | 420 | 650 | 500 | 250 | 10*20 | 900 | 550 | 890 | |||
| SG-300KVA | 180 | 95 | 185 | 100 | 75 | 6*14 | ||||||
| SG-500KVA | 180 | 95 | 185 | 100 | 75 | 6*14 | ||||||
| SG-1000KVA | 180 | 110 | 185 | 100 | 90 | 6*14 | ||||||
| SG-2000KVA | 230 | 125 | 205 | 130 | 100 | 9*16 | ||||||
| SG-3000KVA | 240 | 145 | 215 | 130 | 120 | 9*16 | ||||||
| SG-4000KVA | 240 | 155 | 235 | 130 | 130 | 9*16 | ||||||
| SG-5000KVA | 320 | 160 | 255 | 180 | 115 | 10*20 | 400 | 330 | 480 | |||
| SG-6000KVA | 300 | 165 | 280 | 180 | 140 | 10*20 | 400 | 330 | 480 | |||
Production process
![]()